Mark 968 Series
Sanitary Gas Regulators sizes 3/4" - 2" for biopharm, pharma, food &
beverage low pressure Clean Dry Gas/Air blanketing and inline
pressure regulation
The Mark 968 Sanitary Gas Regulator is the ideal valve
for low pressure gas regulation in pharmaceutical and
food & beverage applications. The self-contained low
pressure gas regulator is for use on tank blanketing and
other very low critical pressure air and gas applications.
The Mark 968 is normally open. Increases in the outlet
pressure are sensed through the aspirator causing the
large elastomer diaphragm to rise, which moves the
plug toward the seat. As outlet pressure decreases, the
diaphragm moves down and moves the plug away from
the seat to increase ow. The lever, which connects the
stem to the diaphragm, amplies diaphragm forces for
tighter shutoff (only available on sizes 3/4" and 1").
The large diaphragm and lever actuation allows the
Mark 968 to act with higher sensitivity compared to
smaller diaphragm pressure regulators. High sensitivity
is important, as the Mark 968 often works with very low
pressure (down to 1" w.c. or 2,5 mbar). This special
actuation improves the accuracy and shutoff of the valve
- two important benets in this style of regulator.
Together, the SST construction, FDA-approved seals
and the tri-clamp connections make this valve well
suited for sterile gas applications and environments.
Features
• Inlet pressures up to 150 psi (10 bar)
• Robust design emergency outlet pressure may
reach 100% of inlet pressure without damaging
valve
• 360° body orientation valve can be installed in
any position, and can be easily repositioned while
in-line
• Easy maintenance seat and plug can be in-
spected without removing body from the line
• Completely self-operated — no external power
source required
• Tight shutoff — soft elastomer plug provides ANSI
Class VI shutoff
• 316/316L SST body/trim and tri-clamp, quick dis-
connect clamp connection
• FDA-approved seals and diaphragms
• Optional electropolishing available
speciFications
Line Sizes: 3/4" (DN20) & 1" (DN25)
End Connections
• Clamped — ISO/DIN or Tri Clamp
• Flanged — 150#, 300#, PN25/40 & sterile anges
Materials
• Body & Housing: SA351 Gr. CF8M 316SS, OR
CF3M 316L
• Seat: ASTM A479 316/316L
• Plug: ASTM A479 316L and FDA-approved Viton
• Diaphragm: Viton (FDA)
• Aspirator Tube: FDA USP Class VI Teon
Service: Air or gas
Shutoff: ANSI Class VI
Temperature Range: -20°F (-29°C) to 200°F (93°C)
Maximum Inlet Pressure: 150 psi (10 bar)
Reduced Pressure Control Range:
• 1.0 to 2.5 inches w.c. (2,5 to 6,2 mbar)
• 2.0 to 5.5 inches w.c. (5,0 to 13,7 mbar)
• 4.0 to 10.0 inches w.c. (10,0 to 24,9 mbar)
• 5.0 to 30.0 inches w.c. (12,4 to 74,7 mbar)
• 0.5 to 1.75 psig (0,03 to 0,12 bar)
• 1.0 to 3.5 psig (0,07 to 0,24 bar)
Orice Sizes (Interchangeable): 1/8" (3mm), 3/16"
(5mm), 1/4" (6mm), 5/16" (8mm), 3/8" (10mm), 7/16"
(11mm), 1/2" (13mm), 9/16" (14mm)
Gas Regulators Mark 968 Sanitary Gas Regulator
Seitenansicht 0
1 2 3 4 5 6 7 8 9 10

Inhaltsverzeichnis

Seite 1 - Mark 968 Series

Steriflow by Jordan Valve 3170 Wasson Road • Cincinnati, OH 45209 513.533.5600 • 800.543.7311 • 513.871.0105 (f)steri[email protected] • www

Seite 2 - Max Flow capacity: scFH

MK968/0812/10K/ABSteriflow, a division of Jordan Valve3170 Wasson Road • Cincinnati, OH 45209 513.533.5600 • 800.543.7311 • 513.871.0105 (f)ster

Seite 3 - Max Flow capacity: nM3/H

Set Pressure Inlet (psi)Orifice Size1/8" 3/16" 1/4" 5/16" 3/8" 7/16" 1/2" 9/16"2" H20(1-2.5" H20)1&qu

Seite 4 - 1" n

Set Pressure Inlet (bar)Orifice Size1/8" 3/16" 1/4" 5/16" 3/8" 7/16" 1/2" 9/16"2" H20(1-2.5" H20)1&qu

Seite 5

Set Pressure Inlet (psi)Orifice Size1/8" 3/16" 1/4" 5/16" 3/8" 7/16" 1/2" 9/16"2" H20(1-2.5" H20)1&qu

Seite 6

Set Pressure Inlet (bar)Orifice Size1/8" 3/16" 1/4" 5/16" 3/8" 7/16" 1/2" 9/16"2" H20(1-2.5" H20)1&qu

Seite 7

Mark 968 Sanitary GaS reGulatorordering scHeMatic (3/4" - 1")Model Size Material/1&2 3&4 5&6 7&8— —Model968 Mark 968 Sanitar

Seite 8 - /H (unsHaded)

Mark 968 SeriesSanitary Gas Regulator (1-1/2" – 2")The 1-1/2" and 2" valves are for use on large tank blanketing applications or o

Seite 9 - 2" n

-8-Mark 968 Sanitary GaS reGulator1-1/2" n2 Flow capacities: scFH (sHaded), nM3/H (unsHaded)RangeOutlet Pressure Set PointAccuracyInlet Pressure2

Seite 10

Mark 968 Sanitary GaS reGulator-9-2" n2 Flow capacities: scFH (sHaded), nM3/H (unsHaded)RangeOutlet Pressure Set PointAccuracyInlet Pressure2.0 p